Canonical: https://echosuite.app/guides/diastolic-sinus/

# Diastolic function assessment: sinus rhythm

Start with the measurements available and explore EchoSuite’s general sinus-rhythm diastolic pathway. The interactive tool keeps incomplete measurements visible and asks the next relevant question.

Created by [Mohammed Kamareddine, MD](https://echosuite.app/about/) · [Sources & educational scope](https://echosuite.app/about/)

[Open interactive calculator →](https://echosuite.app/calculators/#diastolic-sinus)

## Method

2025 ASE Figure 3 · relaxation → LAP markers → supplemental markers → grade

Use the measurement units shown below. Some fields apply only to a selected method or condition; follow the interactive tool’s method choices. The interactive tool keeps missing measurements incomplete and provides its method-specific results and reference context.

## Measurements and acquisition

### Mitral E/A ratio

PW Doppler at the mitral leaflet tips

- Place the PW sample between the mitral leaflet tips.
- Record at end-expiration with a clear E and A wave.
- Measure the requested peaks or trace the requested envelope.

### Septal e′  cm/s

PW tissue Doppler at the mitral annulus

- Place the sample at the septal or lateral mitral annulus.
- Use tissue-Doppler settings and align with annular motion.
- Measure the early diastolic e′ peak and average representative beats.

### Lateral e′  cm/s

PW tissue Doppler at the mitral annulus

- Place the sample at the septal or lateral mitral annulus.
- Use tissue-Doppler settings and align with annular motion.
- Measure the early diastolic e′ peak and average representative beats.

### Average E/e′

PW tissue Doppler at the mitral annulus

- Place the sample at the septal or lateral mitral annulus.
- Use tissue-Doppler settings and align with annular motion.
- Measure the early diastolic e′ peak and average representative beats.

### TR peak velocity  m/s

CW Doppler through the TR jet

- Search RV inflow, apical four-chamber, and subcostal windows; use the highest well-aligned signal.
- Trace the dense primary edge (‘chin’), not faint overgained noise, and reject truncated triangular envelopes when estimating pressure.
- Average three representative beats; in atrial fibrillation average 5–10 beats and exclude post-pause or post-ectopic velocities.

### PASP  mmHg

Contemporaneous cuff or invasive value

- Use a pressure obtained in the same hemodynamic state as the echo.
- Confirm the value is entered in mmHg.
- Do not mix values acquired under different loading conditions.

### LA reservoir strain  %

Enter the measured value in the displayed unit · Optional

- Confirm the variable matches the selected formula.
- Use the unit displayed beside the field.
- Keep measurements from the same representative hemodynamic state.

### Pulmonary vein S/D

Pulsed-wave Doppler · Optional

- Place the sample volume at the specified annulus or outflow tract.
- Align the Doppler beam with flow and record a clean envelope.
- Trace the modal velocity envelope and use the reported VTI.

### LA volume index  mL/m²

Enter the measured value in the displayed unit · Optional

- Confirm the variable matches the selected formula.
- Use the unit displayed beside the field.
- Keep measurements from the same representative hemodynamic state.

### IVRT  ms

Spectral Doppler timing · Optional

- Use a sweep speed that clearly shows the interval boundaries.
- Measure from the specified onset to offset.
- Average representative beats using consistent rhythm handling.

## Sources and method context

American Society of Echocardiography · 2025 · Evaluation of Left Ventricular Diastolic Function and HFpEF Diagnosis · Clinical scope p. 2 · Table 6 p. 16 · Figure 3 p. 17

[Primary reference](https://www.asecho.org/wp-content/uploads/2025/07/Left-Ventricular-Diastolic-Function.pdf)

- Primary and supplemental pathway · Figure 3 · PDF p. 17

Reduced e′, E/e′, TR velocity or PASP, supplemental markers, LAP assignment, and grades 1–3.

- Age-adjusted relaxation · Table 6 · PDF p. 16

Age-adjusted lower limits for septal, lateral, and average mitral annular e′.

- Applicability and exclusions · Clinical considerations p. 2 · Figure 3 caption p. 17

Adult ambulatory or acute-care scope; exclusions for special populations and mitral interventions.

Catalogue review status: Exact guideline locator mapped · clinical sign-off pending

These pages describe the educational tool. Interpret measurements with the complete clinical context and the method’s acquisition limitations.

## Keep exploring

- [Apical four chamber acquisition guide](https://echosuite.app/guides/views/apical-four-chamber/) · [Open in Probe Lab](https://echosuite.app/#a4c)
- [Left atrial pressure calculator: E/e′ method](https://echosuite.app/guides/lap-ee/)
- [Left atrial pressure calculator: mitral regurgitation velocity](https://echosuite.app/guides/lap-mr/)
- [Left atrial volume index calculator: LAVI](https://echosuite.app/guides/la-size/)
- [Left ventricular pressure calculator](https://echosuite.app/guides/lv-pressure/)

[All echo guides](https://echosuite.app/guides/) · [Learning paths](https://echosuite.app/learn/)