Canonical: https://echosuite.app/guides/diastolic-transplant/

# Diastolic assessment after heart transplant: sinus rhythm

Review the heart-transplant diastolic pathway for sinus rhythm and the measurement context supplied with the tool.

Created by [Mohammed Kamareddine, MD](https://echosuite.app/about/) · [Sources & educational scope](https://echosuite.app/about/)

[Open interactive calculator →](https://echosuite.app/calculators/#diastolic-transplant)

## Method

2025 ASE Figure 5 · average E/e′; intermediate values use E/SRIVR or TR velocity

Use the measurement units shown below. Some fields apply only to a selected method or condition; follow the interactive tool’s method choices. The interactive tool keeps missing measurements incomplete and provides its method-specific results and reference context.

## Measurements and acquisition

### Average E/e′

PW tissue Doppler at the mitral annulus

- Place the sample at the septal or lateral mitral annulus.
- Use tissue-Doppler settings and align with annular motion.
- Measure the early diastolic e′ peak and average representative beats.

### E/SRIVR

Enter the measured value in the displayed unit

- Available
- Unavailable
- Confirm the variable matches the selected formula.
- Use the unit displayed beside the field.
- Keep measurements from the same representative hemodynamic state.

### Mitral E / SRIVR  cm

Enter the measured value in the displayed unit

- Confirm the variable matches the selected formula.
- Use the unit displayed beside the field.
- Keep measurements from the same representative hemodynamic state.

### TR peak velocity  m/s

CW Doppler through the TR jet

- Search RV inflow, apical four-chamber, and subcostal windows; use the highest well-aligned signal.
- Trace the dense primary edge (‘chin’), not faint overgained noise, and reject truncated triangular envelopes when estimating pressure.
- Average three representative beats; in atrial fibrillation average 5–10 beats and exclude post-pause or post-ectopic velocities.

## Sources and method context

American Society of Echocardiography · 2025 · Evaluation of Left Ventricular Diastolic Function and HFpEF Diagnosis · Table 7 p. 20 · Figure 5 p. 23

[Primary reference](https://www.asecho.org/wp-content/uploads/2025/07/Left-Ventricular-Diastolic-Function.pdf)

- Transplant pathway · Figure 5 · PDF p. 23

Average E/e′ outer branches and E/SRIVR or TR-velocity resolution of intermediate values.

- Transplant limitations · Section 15B · PDF pp. 22–23

Sinus-rhythm scope and the limitation of diastolic indices for graft-rejection diagnosis.

Catalogue review status: Exact guideline locator mapped · clinical sign-off pending

These pages describe the educational tool. Interpret measurements with the complete clinical context and the method’s acquisition limitations.

## Keep exploring

- [Apical four chamber acquisition guide](https://echosuite.app/guides/views/apical-four-chamber/) · [Open in Probe Lab](https://echosuite.app/#a4c)
- [Left atrial pressure calculator: E/e′ method](https://echosuite.app/guides/lap-ee/)
- [Left atrial pressure calculator: mitral regurgitation velocity](https://echosuite.app/guides/lap-mr/)
- [Left atrial volume index calculator: LAVI](https://echosuite.app/guides/la-size/)
- [Left ventricular pressure calculator](https://echosuite.app/guides/lv-pressure/)

[All echo guides](https://echosuite.app/guides/) · [Learning paths](https://echosuite.app/learn/)
