# Mitral prosthetic valve calculator: EOA, DVI and PPM

Explore effective orifice area, Doppler velocity index and prosthesis–patient mismatch inputs for the mitral prosthesis tool.

Created by [Mohammed Kamareddine, MD](https://echosuite.app/about/) · [Sources & educational scope](https://echosuite.app/about/)

[Open interactive calculator →](https://echosuite.app/calculators/#mitral-prosthesis)

## Method

EOA = LVOT area × LVOT VTI ÷ MV prosthesis VTI; DVI = MV prosthesis VTI ÷ LVOT VTI

Use the measurement units shown below. Some fields apply only to a selected method or condition; follow the interactive tool’s method choices. The interactive tool keeps missing measurements incomplete and provides its method-specific results and reference context.

## Measurements and acquisition

### Measurement

Enter the measured value in the displayed unit

- EOA & DVI
- Patient–prosthesis mismatch
- Confirm the variable matches the selected formula.
- Use the unit displayed beside the field.
- Keep measurements from the same representative hemodynamic state.

### LVOT VTI  cm

Pulsed-wave Doppler

- Place the sample volume at the specified annulus or outflow tract.
- Align the Doppler beam with flow and record a clean envelope.
- Trace the modal velocity envelope and use the reported VTI.

### Mitral prosthesis VTI  cm

Continuous-wave Doppler trace

- Use the same aligned CW recording as the peak velocity.
- Trace the outer edge of the dense envelope for the relevant phase.
- Use the machine-reported VTI in centimeters.

### LVOT diameter  cm

2D echo · inner-edge measurement

- Use the specified view and cardiac phase.
- Align the calipers perpendicular to the structure’s long axis.
- Measure inner edge to inner edge and avoid oblique foreshortening.

### Body surface area  m²

Record the units, date and measurement source

- Use measured height and weight where feasible. Record the units, date and whether a value was reported or estimated.
- Fluid status and weight changes affect BSA. Document any substituted weight; do not silently replace measured weight with ideal or dry weight.
- Use the unit named by the field. BSA is in m²; height and weight can be converted in the Body surface area calculator. Keep the formula with serial indexed results.

### Body mass index  kg/m²

Enter the measured value in the displayed unit · Optional

- Confirm the variable matches the selected formula.
- Use the unit displayed beside the field.
- Keep measurements from the same representative hemodynamic state.

### Valve structure & motion

Enter the measured value in the displayed unit

- Normal
- Abnormal
- Uncertain
- Confirm the variable matches the selected formula.
- Use the unit displayed beside the field.
- Keep measurements from the same representative hemodynamic state.

### EOA vs model / size reference

Enter the measured value in the displayed unit

- Within 1 SD
- Outside 1 SD
- Not known
- Confirm the variable matches the selected formula.
- Use the unit displayed beside the field.
- Keep measurements from the same representative hemodynamic state.

### Continuity volume matching

Enter the measured value in the displayed unit

- Valid · no significant MR / AR
- Limited
- Uncertain
- Confirm the variable matches the selected formula.
- Use the unit displayed beside the field.
- Keep measurements from the same representative hemodynamic state.

### Stable postoperative baseline

Enter the measured value in the displayed unit

- Stable
- New change
- Not known
- Confirm the variable matches the selected formula.
- Use the unit displayed beside the field.
- Keep measurements from the same representative hemodynamic state.

## Sources and method context

American Society of Echocardiography · 2024 · Guidelines for the Evaluation of Prosthetic Valve Function With Cardiovascular Imaging · EOA and DVI JASE pp. 9–10 · mitral evaluation pp. 24–25 · Table 7 p. 20 (BMI-adjusted PPM and prerequisites) · Table 11 p. 27

[Primary reference](https://www.asecho.org/wp-content/uploads/2024/01/PIIS0894731723005333.pdf)

- Mitral EOA, DVI and PPM · Section III.B(i) · JASE pp. 24–25

EOA from LVOT stroke volume / mitral VTI; inverse VTI ratio for DVI. Table 7 supplies BMI-adjusted mitral PPM bands, requiring normal structure/motion and EOA within 1 SD of the model/size reference.

- Limitations · Section III.B(i) · JASE pp. 24–25

Important MR can underestimate LVOT-based mitral EOA; significant AR also breaks volume matching. PHT-derived EOA is invalid. Integrate prosthesis type, size, flow, rhythm and baseline.

Catalogue review status: Exact guideline locator mapped · clinical sign-off pending

These pages describe the educational tool. Interpret measurements with the complete clinical context and the method’s acquisition limitations.

## Keep exploring

- [Apical four chamber acquisition guide](https://echosuite.app/guides/views/apical-four-chamber/) · [Open in Probe Lab](https://echosuite.app/#a4c)
- [Apical five chamber acquisition guide](https://echosuite.app/guides/views/apical-five-chamber/) · [Open in Probe Lab](https://echosuite.app/#a5c)
- [Aortic prosthetic valve calculator: EOA, DVI and PPM](https://echosuite.app/guides/aortic-prosthesis/)
- [Surgical aortic prosthesis · obstruction calculator](https://echosuite.app/guides/aortic-prosthesis-screen/)
- [Aortic prosthesis · serial comparison calculator](https://echosuite.app/guides/aortic-prosthesis-serial/)
- [Mitral prosthesis · obstruction calculator](https://echosuite.app/guides/mitral-prosthesis-screen/)

[All echo guides](https://echosuite.app/guides/) · [Learning paths](https://echosuite.app/learn/)