Systolic ΔP = 4Vsys²; estimated PASP = SBP − ΔP; estimated mPAP = MAP − complete-cycle mean ΔP

Use the measurement units shown below. Some fields apply only to a selected method or condition; follow the interactive tool’s method choices. The interactive tool keeps missing measurements incomplete and provides its method-specific results and reference context.

Measurements and acquisition

Clinical question

Enter the measured value in the displayed unit

  • PA systolic pressure
  • Mean PA pressure
  • Ductal gradient only
  • Confirm the variable matches the selected formula.
  • Use the unit displayed beside the field.
  • Keep measurements from the same representative hemodynamic state.

Observed ductal flow

Enter the measured value in the displayed unit

  • Not established
  • All left → right
  • Bidirectional
  • All right → left
  • Confirm the variable matches the selected formula.
  • Use the unit displayed beside the field.
  • Keep measurements from the same representative hemodynamic state.

Peak systolic PDA velocity m/s

Continuous-wave Doppler

  • Align the CW cursor as parallel as possible to the jet.
  • Acquire a dense, complete envelope without truncation.
  • Measure the highest absolute velocity on the selected envelope.

Systolic blood pressure mmHg

Contemporaneous cuff or invasive value

  • Use a pressure obtained in the same hemodynamic state as the echo.
  • Confirm the value is entered in mmHg.
  • Do not mix values acquired under different loading conditions.

Complete-cycle mean gradient mmHg

Complete traced CW envelope

  • Align through the valve or shunt and record a complete envelope.
  • Trace the modal velocity envelope using the machine tool.
  • Use the machine-calculated mean gradient in mmHg.

Mean arterial pressure mmHg

Contemporaneous cuff or invasive value

  • Use a pressure obtained in the same hemodynamic state as the echo.
  • Confirm the value is entered in mmHg.
  • Do not mix values acquired under different loading conditions.

Sources and method context

ASE · AHA / ACC · primary Doppler studies · 2025 · PDA acquisition, pressure estimation and whole-shunt assessment · ASE pediatric TTE 2024 pp. 162–163 · TNE 2024 pp. 185–188, Table 5 · Musewe et al. 1987

Primary reference

Catalogue review status: Exact guideline locator mapped · clinical sign-off pending

These pages describe the educational tool. Interpret measurements with the complete clinical context and the method’s acquisition limitations.

Keep exploring

All echo guides · Learning paths

About EchoSuite

Explore echocardiography.

Mohammed Kamareddine, MD

Explore EchoSuite

Sources & licences

Original EchoSuite teaching overlays and software © Mohammed Kamareddine, MD. Source anatomy and clinical media retain their listed rights and licences.

Acquisition guidance retains the app’s source wording: Mitchell C, Rahko PS, Blauwet LA, et al. Guidelines for Performing a Comprehensive Transthoracic Echocardiographic Examination in Adults. J Am Soc Echocardiogr. 2019;32(1):1–64. Primary reference.

Michroma by Vernon Adams · Font licence. Three.js · MIT licence.

EchoSuite is an educational product, not a diagnostic medical device.